5600 5600 econominder owner s manual for questions or in case of emergency please call your local service technician preferably the one who.
Fleck 5600 metered water softener manual.
It was updated from the old mechanical meter to the 21st century sxt electronics.
Install the water softener with the inlet outlet and drain connections made according to manufacturer s recommendations and to meet applicable plumbing codes.
Drain line is securely in place before the use of the water softener system.
Caution water pressure is not to exceed 125 psi 8 6 bar water temperature is not to exceed 110 f 43 c.
Install the water softener with the inlet outlet and 9.
The 5600 fleck valve is the most popular water softener control valve on the planet and offers a rigid noryl valve body with low power consumption and a precision piston seal spacer assembly.
Programming the fleck 5600 meter valve.
Downflow softener 120v 60hz u s.
Bypass valves always provide for the installation of a bypass valve if unit is not equipped with one.
Power cord low water piston 1 injector 0 25 gpm blfc enclosed housing silver blue label 560002 020 downflow softener 24v 60hz less transformer low water piston 1 injector 0 25 gpm blfc enclosed housing silver blue label.
Location of softener and drain the softener should be located close to a drain to prevent air breaks and back flow.
If you like the classic mechanical meter you will love the electronic version which has fewer parts and is virtually.
When the system regenerates there will be increased flow via this tubing which may cause the tubing to become loose.
Only used on metered water softners it indicates water is flowing.
Once the water is cleared up a manual regeneration should be run.
6 model 5600 5600 econominder model 5600 installation and start up procedures note.
Drain cannot be elevated more than 36 inches or exceed 20 feet in length.
The brine tank should be located within 20 feet of the water softener.
View and download fleck 5600 service manual online.
It may clear up almost immediately or it may take a couple of hours.
Water conditioner flow diagrams water conditioner flow diagrams service position backwash position preliminary rinse position brine position fleck 7 5600 service manual.
Covers standard water softeners using a separate brine tank.
Before start up a few simple steps must be followed to program the fleck 5600 meter valve.