In general a sprinkler is activated by the heat put off by the fire once it reaches a certain temperature at the ceiling around that particular head.
Fire sprinkler system components.
Reliable s line of system components completes our portfolio of manufactured products and may be conveniently bundled and shipped to your shop or job site location.
All sprinkler systems have to be connected to a fire alarm.
As a leader in the fire protection industry since 1920 reliable system components are supported by our customer service and technical support teams.
At guardian fire protection services we want to clear up some of the mysteries behind key fire sprinkler inspection terms with a list of all the most important components of your fire sprinkler system.
8 fire department connection.
Fire sprinkler system components.
An alarm test valve is for testing the system.
The pressure switch is an electro mechanical device that monitors a fire sprinkler system for a fall in water pressure after the alarm valve.
When you activate the system the.
In addition to the main components of the fire sprinkler system there are a series of ancillary support components that regularly form part of an automatic fire sprinkler system.
Note that fire pumps are normally powered by electricity.
If a fire pump is used with the sole purpose of supplying water for a fire sprinkler system it is considered a sprinkler booster pump.
Color of the liquid within the bulb indicate the listed activation temperature of the sprinkler and can be found in nfpa 13 2002 2016 table 6 2 5 1.
Connection used by the fire department to pump water into the fire sprinkler or standpipe system to supplement the building s water supply.
Control valve the stop valve is usually locked in the open position and painted bright red so you can see it.
A fire sprinkler system is an active fire protection method consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system onto which fire sprinklers are connected.
It can work even if the system is not on.
Although historically only used in factories and large commercial buildings systems for homes and small buildings are now available at a cost effective price.
The alarm test valve will run the fire pump but it will not flood your building.
Nyc codes provide a list of requirements for the backup power systems for fire pumps ensuring their operation even if the electric service is interrupted during an emergency.
You need to test your fire protection system on a regular basis.
Alarm check valve is a device used to notify the house or building of a possible emergency.
One of the most important components of a fire protection system is the automatic fire sprinklers.
The alarm in the form of an electrical bell or a motor gong will sound when water flows through the alarm valve.