The annual fire pump flow test can identify deterioration of the fire pump or impairments to the water supply.
Fire pump testing trailer.
1 fire pump can supply the full system demand as provided by the owner.
Pump testing can now be done at your fire station.
What needs to done.
It is preferable to keep the water source below the pump.
Below is an overview of the inspection and testing activities that.
Making drafting pits and other pump testing methods obsolete.
Easyflow is the finest fire pump test trailer available in today s market featuring impressive speed precision accuracy and ease of use.
Also this environmentally enhanced unit saves you money while increasing revenues.
We are manufacturer supplier exporter of trailer mounted fire pump fire fighting pumps and our setup is situated at kolhapur maharashtra india key features single stage centrifugal pump is directly coupled with a suitable engine and mounted on a trailer for surface transportation.
2 fire pump test results are no less than 95 percent of the flow rates and pressures at each point for either a or b.
The draft commander 3000 mobile fire pump testing training unit allows you to perform a true pump test from draft with clean water.
Testing ensures that your engine and fire pump are performing with the correct horsepower and pumping the correct amount of gpm.
Mobile fire pump testing trailers.
The easyflow unit offers accurate testing simplifies testing procedures reduces costs and boosts your company image.
If you will be testing from a hydrant it must be capable of flowing the rated capacity of the pump.
Fire pumps on apparatus shall be service tested in accordance with the applicable requirements of nfpa 1911.
Mobile fire pump testing on site mobile service maintenance call.
You must allow ample space for discharging the water and add the static pressure of the hydrant to the net pump pressure.
Some states require that the person conducting the annual fire pump test be certified.
A original unadjusted field.
888 595 8323 fire pump testing is an essential and important part of apparatus maintenance and safety in order to ensure the fire pump is in an operating condition free of physical damage and is capable of providing continuous delivery for required fire protection demands.
Inspection testing and maintenance requirements are outlined in nfpa 25 standard for the inspection testing and maintenance of water based fire protection systems.
The field acceptance test is conducted on newly installed pumps and demonstrates that all the fire pump unit components perform according to manufacturers specifications as well as proving that the water supply is adequate.