In addition to all of the components of a fire door assembly.
Fire door inspection checklist pdf.
E fire door assembly inspection checklist beginning with the 2007 edition and continuing with subsequent editions nfpa 80 standard for fire doors and other opening protectives section 5 2 inspection and testing requires all fire door assemblies to be inspected not less than annually.
The assembly is composed of the fire door frame fire exit hardware door closers hinges locks door bolts and other door components that when combined provide varying degrees of fire protection that is contingent on the door fire rating e g.
We are certified to perform detailed 13 points fire doors inspection.
Throughout the checklist there will be sub checklists for each section to explore a more detailed assessment of the areas.
The frequency of each inspection should be determined by assessing among other things the amount of use the door is subjected to the criticality of the area and who it protects.
This may result in a requirement for the doors to be.
The more regular the checks the higher the levels of safety provided.
The door operates smoothly and quietly without binding or scraping grinding noises.
Fire doors basic guidance checklist introduction.
The 2012 edition of the life safety code nfpa 101 requires facilities to complete annual fire and smoke door inspection and testing.
In this process street fire inspection checklist we cover how to run a fire safety inspection on a residential or commercial building.
Manual fire alarm boxes ion detectors photo detectors duct detectors heat detectors waterflow switches supervisory switches other specify.
This inspection should be run annually at least.
Checks visual and operating checks only door door door door door door warning keep hands away from the door door operator safety devices operation.
Section 18 2 2 2 1 19 2 2 2 1 requires compliance with section 7 2 1 and section 7 2 1 15 2 requires compliance with nfpa 80 standard.
Check the door frame bolts hinges locks fire exit hardware door closers and other significant parts for defects in need of repair or replacement.
This detailed fire door inspection checklist can be used to survey the overall condition of fire doors.
Fire door assembly inspection checklist the 2007 and 2010 editions of nfpa 80 standard for fire do ors and other opening protectives section 5 2 inspections require all fire doors to be inspect ed not less than annually.
Our fire smoke door experts will provide a thorough inspection of all the doors in the building to ensure they are safe and complying with the nfpa code and prepare a detailed report on the condition and function of the fire door on your facilities.